Trigger

SCPI Commands :

[SOURce<HW>]:BB:ARBitrary:TRIGger:PTIMe
[SOURce<HW>]:BB:ARBitrary:TRIGger:RMODe
[SOURce<HW>]:BB:ARBitrary:TRIGger:SLENgth
[SOURce<HW>]:BB:ARBitrary:TRIGger:SLUNit
[SOURce<HW>]:BB:ARBitrary:TRIGger:SMODe
[SOURce<HW>]:BB:ARBitrary:TRIGger:SOURce
[SOURce<HW>]:BB:ARBitrary:[TRIGger]:SEQuence
class TriggerCls[source]

Trigger commands group definition. 29 total commands, 6 Subgroups, 7 group commands

get_ptime() str[source]
# SCPI: [SOURce<HW>]:BB:ARBitrary:TRIGger:PTIMe
value: str = driver.source.bb.arbitrary.trigger.get_ptime()

Queries the internal processing time. The processing time is the elapsed time between the input of the external trigger event and the output of the baseband signal.

return:

arb_trig_proc_time: string

get_rmode() TrigRunMode[source]
# SCPI: [SOURce<HW>]:BB:ARBitrary:TRIGger:RMODe
value: enums.TrigRunMode = driver.source.bb.arbitrary.trigger.get_rmode()

Queries the status of waveform output.

return:

rmode: STOP| RUN

get_sequence() DmTrigMode[source]
# SCPI: [SOURce<HW>]:BB:ARBitrary:[TRIGger]:SEQuence
value: enums.DmTrigMode = driver.source.bb.arbitrary.trigger.get_sequence()

The command selects the trigger mode.

return:

sequence: AUTO| RETRigger| AAUTo| ARETrigger| SINGle

get_sl_unit() UnitSlB[source]
# SCPI: [SOURce<HW>]:BB:ARBitrary:TRIGger:SLUNit
value: enums.UnitSlB = driver.source.bb.arbitrary.trigger.get_sl_unit()

Defines the unit for the entry of the length of the signal sequence to be output in the Single trigger mode.

return:

sl_unit: SEQuence| SAMPle

get_slength() int[source]
# SCPI: [SOURce<HW>]:BB:ARBitrary:TRIGger:SLENgth
value: int = driver.source.bb.arbitrary.trigger.get_slength()

Defines the length of the signal sequence that is output in the SINGle trigger mode.

return:

slength: integer Maximun value dependents on the selected units [:SOURcehw]:BB:ARBitrary:TRIGger:SLUNit as follows: SAMPle: Max = 232-1 SEQuence: Max = 1000 Range: 1 to dynamic

get_smode() ArbTrigSegmModeNoEhop[source]
# SCPI: [SOURce<HW>]:BB:ARBitrary:TRIGger:SMODe
value: enums.ArbTrigSegmModeNoEhop = driver.source.bb.arbitrary.trigger.get_smode()

Selects the extended trigger mode for multi segment waveforms.

return:

smode: SAME| NEXT| SEQuencer| NSEam NSEam = Next Segment Seamless

get_source() TrigSour[source]
# SCPI: [SOURce<HW>]:BB:ARBitrary:TRIGger:SOURce
value: enums.TrigSour = driver.source.bb.arbitrary.trigger.get_source()


    INTRO_CMD_HELP: Selects the trigger signal source and determines the way the triggering is executed. Provided are:

    - Internal triggering by a command (INTernal)

    :return: source: INTernal| EXTernal
set_sequence(sequence: DmTrigMode) None[source]
# SCPI: [SOURce<HW>]:BB:ARBitrary:[TRIGger]:SEQuence
driver.source.bb.arbitrary.trigger.set_sequence(sequence = enums.DmTrigMode.AAUTo)

The command selects the trigger mode.

param sequence:

AUTO| RETRigger| AAUTo| ARETrigger| SINGle

set_sl_unit(sl_unit: UnitSlB) None[source]
# SCPI: [SOURce<HW>]:BB:ARBitrary:TRIGger:SLUNit
driver.source.bb.arbitrary.trigger.set_sl_unit(sl_unit = enums.UnitSlB.SAMPle)

Defines the unit for the entry of the length of the signal sequence to be output in the Single trigger mode.

param sl_unit:

SEQuence| SAMPle

set_slength(slength: int) None[source]
# SCPI: [SOURce<HW>]:BB:ARBitrary:TRIGger:SLENgth
driver.source.bb.arbitrary.trigger.set_slength(slength = 1)

Defines the length of the signal sequence that is output in the SINGle trigger mode.

param slength:

integer Maximun value dependents on the selected units [:SOURcehw]:BB:ARBitrary:TRIGger:SLUNit as follows: SAMPle: Max = 232-1 SEQuence: Max = 1000 Range: 1 to dynamic

set_smode(smode: ArbTrigSegmModeNoEhop) None[source]
# SCPI: [SOURce<HW>]:BB:ARBitrary:TRIGger:SMODe
driver.source.bb.arbitrary.trigger.set_smode(smode = enums.ArbTrigSegmModeNoEhop.NEXT)

Selects the extended trigger mode for multi segment waveforms.

param smode:

SAME| NEXT| SEQuencer| NSEam NSEam = Next Segment Seamless

set_source(source: TrigSour) None[source]
# SCPI: [SOURce<HW>]:BB:ARBitrary:TRIGger:SOURce
driver.source.bb.arbitrary.trigger.set_source(source = enums.TrigSour.BBSY)


    INTRO_CMD_HELP: Selects the trigger signal source and determines the way the triggering is executed. Provided are:

    - Internal triggering by a command (INTernal)

    :param source: INTernal| EXTernal

Cloning the Group

# Create a clone of the original group, that exists independently
group2 = driver.source.bb.arbitrary.trigger.clone()

Subgroups